CFM

Cassette monosplit

360° airfolw with round corners

Its benefits

  • 7ACEL1740 remote control included
  • Design compact
  • Alarm output and dry contact
  • Integrated condensate pump
  • Soufflage round flow 360°"
  • G1 filter included
  • Auxiliary air supply and fresh air supply

The + "sustainable development":

    The + "user":

    • An attractive solution
    • Homogeneous airflow distribution in the room for greater comfort

    The + "installer":

    • Suitable for rooms with limited space
    • Parameters can be read on the indoor unit

    The + "technology":

    • High corrosion resistance with the Golden Fin
    • Characteristics products
    • R410A fluid R410A fluid
      Multiflow 360° Multiflow 360°
      Golden fin treatment Golden fin treatment
      Air filter Air filter
      Fresh air Fresh air
      I Feel I Feel
      Night mode Night mode
      Programmable timer Programmable timer
      Auto Restart (Memory) Auto Restart (Memory)
      Remote control lock Remote control lock
      Error code via indoor unit Error code via indoor unit
      Self diagnostic Self diagnostic
      Integrated water pump Integrated water pump
      Alarm output Alarm output
      Dry contact on/off Dry contact on/off
      Auxiliary heater Auxiliary heater
      Technician test mode Technician test mode
      Unités intérieuresAW-CFM012-N11AW-CFM018-N11AW-CFM024-N11AW-CFM036-N11AW-CFM036T-N11AW-CFM048-N11
      Unités extérieures 1
      ~230V - 50Hz
      AWAU-YFFA012-H11 AWAU-YFFA018-H11 AWAU-YFFA024-H11 AWAU-YFFA036-H11
      Unités extérieures 3
      ~400V - 50Hz - N
      AWAU-YFFA036-H13 AWAU-YFFA048-H13
      Cooling
      Rated capacitykw3.625.616.969.8410.4413.15
      SEER / Energy label / A / D / D / D / C / E
      Operating limits°C18°/46° Dry bulb18°/46° Dry bulb18°/46° Dry bulb18°/46° Dry bulb18°/46° Dry bulb18°/46° Dry bulb
      Heating
      Rated capacitykW3.725.637.6911.2011.6314.06
      SCOP (average climate) / Energy label (average climate) / E / C / D / E / D / D
      Operating limits°C-7°/24° Dry bulb-7°/24° Dry bulb-7°/24° Dry bulb-7°/24° Dry bulb-7°/24° Dry bulb-7°/24° Dry bulb
      Indoor unit
      Sound power level (LS/MS/HS/SS)dB(A)34/38/4234/40/4639/43/4844/48/5145/48/5146/51/58
      Airflow (LS/MS/HS/SS)m³/h413/504/307513/625/801787/945/10921356/1547/17711297/1494/17311305/1566/1990
      Code7SP0422677SP0422687SP0422697SP0422707SP0422727SP042271
      Energy label
      Outdoor unit
      Sound power level (LS/MS/HS/SS)m³/h180020002800500038006000
      Outline Dimensions (WxHxD)mm900x595x345900x625x348965x775x3951090x885x5001090x875x5001032x1307x443
      Net Weightkg32/34.536.5/39.752.7/56.179.5/85.374.4/78.997/107
      Code 1~230V - 50 Hz 7SP063065 7SP063066 7SP063067 7SP063072
      Code 3~400V - 50 Hz 7SP063069 7SP063070
      Energy label
      Alimentation
      Phase/Tension/Frequency1P/230V/50Hz1P/230V/50Hz1P/230V/50Hz1P/230V/50Hz3P/N/400V/50Hz3P/N/400V/50Hz
      Power supply sideIndoorIndoorIndoorOutdoorOutdoorIndoor
      Power cable sectionmm²3x2.53x2.53x2.53x45x2.55x2.5
      Fuse rating am A16163250  25 32 
      Electrical connectionsmm²3x2.5 + 2x0.753x2.5 + 2x1 + 2x0.753x2.5 + 2x1 + 2x0.23x1.5 + 3x1 + 2x0.23x1.5 + 3x15x2.5 + 3x1
      Liaison frigorifique
      Suction pipe diameterinches1/2”1/2”5/8”3/4”3/4”3/4”
      Liquid pipe diameterinches1/4”1/4”3/8”3/8”3/8”3/8”
      Max lengthm152525303050
      Max heightm81515202030
      Refrigerant / GWPR410A/2088R410A/2088R410A/2088R410A/2088R410A/2088R410A/2088
      Charge (5 m)kg11.51.82.52.853.3
      Additional chargeg/m
      Actions Request a quote Request a quote Request a quote Request a quote Request a quote Request a quote
    • Accessories and options
    • Wireless controller RC08C

      Wireless controller RC08C

      Réf. : 7ACEL1740

      Appareils : DDM/DFM

      Timer, eco mode, “Follow me” option, swing, technician mode, heating only mode.

      Wired single control RCW6

      Wired single control RCW6

      Réf. : 7ACEL1704

      Appareils : FFM/CFM/DFM

      Mode, fan speed, real time, timer, temperature, weekly timer and swing.

      Wired single control RCW8

      Wired single control RCW8

      Réf. : 7ACEL1706

      Appareils : HKD/XDM/FFM/CFM

      Mode, fan speed, timer On/Off, temperature and swing.

      Central controller RCW16

      Central controller RCW16

      Réf. : 7ACEL1707

      Appareils : FFM/CFM/DFM

      Controls up to 64 indoor units with individual setting failure codes indication, ON-OFF dry contact, last operation memory, ModBus.

      BMS gateway

      BMS gateway

      Réf. : 7ACEL1708

      Appareils : DDM/FDM/CDM/FFM/CFM/DFM

      Maximum 1024 units could be connected (16 gateways).
    • Technical documentation

    These products

    may also be interested for you

    CDM R32

    Cassette multisplit

    Cassette multisplit

    CDM R32
    See the product

    GCAO

    Water source fixed speed - Compatible with HHF-CAF-DAF

    Water source fixed speed - Compatible with HHF-CAF-DAF

    GCAO
    See the product

    Water FlowLogic

    Outdoor unit - Water condensing VRF

    Outdoor unit - Water condensing VRF

    Water FlowLogic
    See the product

    Wellea Split

    Split heat pump R32

    Split heat pump R32

    Wellea Split
    See the product

    DFM

    Ducted high static pressure monosplit

    Ducted high static pressure monosplit

    DFM
    See the product

    DDM R32

    Ducted medium static pressure monosplit & multisplit

    Ducted medium static pressure monosplit & multisplit

    DDM R32
    See the product

    Are you an individual ?

    Airwell general public