CDM R32

Cassette multisplit

360° airfolw with round corners

Its benefits

  • 7ACEL1740 remote control included
  • Compact design
  • Alarm output and dry contact
  • Round flow 360° blown air output
  • Multisplit compatible
  • R32/R410A compatible
  • Auxiliary air supply and fresh air supply

The + "sustainable development":

  • High energy class A++ (cooling mode)/A+ (heating mode)

The + "user":

  • Homogeneous airflow distribution in the room for greater comfort
  • User comfort (“I Feel” as option)

The + "installer":

  • Suitable for rooms with limited space
  • Parameters can be read on the indoor unit

The + "technology":

  • High corrosion resistance with the Golden Fin
  • Electronic expansion valve
  • Characteristics products
  • R32 fluid R32 fluid
    Flexy Match Flexy Match
    DC Inverter DC Inverter
    Electronic expansion valve Electronic expansion valve
    Multiflow 360° Multiflow 360°
    Golden fin treatment Golden fin treatment
    Air filter Air filter
    I Feel I Feel
    Night mode Night mode
    Programmable timer Programmable timer
    Auto Restart (Memory) Auto Restart (Memory)
    Error code via indoor unit Error code via indoor unit
    Self diagnostic Self diagnostic
    Integrated water pump Integrated water pump
    Alarm output Alarm output
    Dry contact on/off Dry contact on/off
    Heating only mode Heating only mode
    Unités intérieuresAW-CDM009X-N91AW-CDM012-N91AW-CDM018-N91AW-CDM024-N91AW-CDM036-N91AW-CDM036-N91AW-CDM048-N91
    Unités extérieures 1
    ~230V - 50Hz
    AW-YDFA012-H91 AW-YDFA018-H91 AW-YDFA024-H91 AW-YDFA036-H91
    Unités extérieures 3
    ~400V - 50Hz - N
    AW-YDFA036-H93 AW-YDFA048-H93
    Cooling
    Rated capacitykw2.6 (0.8-3.3)3.52 (1.52-5.38)5.28 (2.9-5.45)7.03 (2.23-8.21)10.55 (2.64-12.02)10.55 (2.64-12.02)14.00 (4.76-14.58)
    SEER / Energy label /6.4/A++ / A++6.1/A++ / A++6.1/A++ / A++6.1/A++ / A++6.1/A++ / A++6.1/A++ / A++
    Operating limits°C-15°/50° Dry bulb-15°/50° Dry bulb-15°/50° Dry bulb-15°/50° Dry bulb-15°/50° Dry bulb-15°/50° Dry bulb-15°/50° Dry bulb
    Heating
    Rated capacitykW2.9 (0.85-3.7)4.4 (1.03-5.57)5.42 (2.37-6.1)7.62 (2.43-8.65)11.14 (2.93-13.19)11.14 (2.93-13.19)16.1 (3.93-16.77)
    SCOP (average climate) / Energy label (average climate) /4.0/A+ / A+4.0/A+ / A+4.0/A+ / A+4.0/A+ / A+4.0/A+ / A+4.0/A+ / A+
    Operating limits°C-15°/24° Dry bulb-15°/24° Dry bulb-15°/24° Dry bulb-15°/24° Dry bulb-15°/24° Dry bulb-15°/24° Dry bulb-15°/24° Dry bulb
    Indoor unit
    Sound power level (LS/MS/HS/SS)dB(A)54565659616265
    Airflow (LS/MS/HS/SS)m³/h400/504/580416/504/617540/625/7201032/1200/13781438/1620/17751438/1620/17751381/1568/1715
    Code7SP042261X7SP0422627SP0422637SP0422647SP0422657SP0422657SP042266
    Energy label
    Outdoor unit
    Sound power level (LS/MS/HS/SS)m³/h6265666868 72
    Outline Dimensions (WxHxD)mm800x554x333800x554x333845x702x363946x810x410946x810x410952x1333x415
    Net Weightkg34.7/37.533.7/36.649.4/52.866.8/73.481.5/87.0106.7/119.9
    Code 1~230V - 50 Hz 7SP063050 7SP063051 7SP063052 7SP063053
    Code 3~400V - 50 Hz 7SP063054 7SP063055
    Energy labelSee the label
    Alimentation
    Phase/Tension/Frequency1P/230V/50Hz1P/230V/50Hz1P/230V/50Hz1P/230V/50Hz1P/230V/50Hz3P/400V/50Hz3P/400V/50Hz
    Power supply sideOutdoorOutdoorIndoor & OutdoorIndoor & OutdoorIndoor & OutdoorIndoor & Outdoor
    Power cable sectionmm²3x1.53x2.53x1.5+3x2.53x1.5+3x43x1.5+3x43x1.5+5x2.5
    Fuse rating am A161610+2510+3010+2010+25
    Electrical connectionsmm²4x1.04x1.54x1.52x0.52x0.52x0.52x0.5
    Liaison frigorifique
    Suction pipe diameterinches3/8”3/8”1/2”5/8”5/8”5/8”5/8”
    Liquid pipe diameterinches1/4”1/4”1/4”3/8”3/8”3/8”3/8”
    Max lengthm253050656565
    Max heightm102025303030
    Refrigerant / GWPR32/675R32/675R32/675R32/675R32/675R32/675
    Charge (5 m)kg0.871.151.52.42.42.8
    Additional chargeg/m121224 24 24 24
    Actions Request a quote Request a quote Request a quote Request a quote Request a quote Request a quote Request a quote
  • Related products
  • YDZC - Multisplit duo

    YDZC - Multisplit duo

    ...

  • Accessories and options
  • Wireless controller RC08C

    Wireless controller RC08C

    Réf. : 7ACEL1740

    Appareils : DDM/DFM

    Timer, eco mode, “Follow me” option, swing, technician mode, heating only mode.

    Wired single control RCW11

    Wired single control RCW11

    Réf. : 7ACEL1774

    Appareils : FDM/CDM

    Weekly timer, mode, fan speed, timer On/Off, “I Feel” function, temperature.

    BMS gateway

    BMS gateway

    Réf. : 7ACEL1708

    Appareils : DDM/FDM/CDM/FFM/CFM/DFM

    Maximum 1024 units could be connected (16 gateways).

    Test tool

    Test tool

    Réf. : 7ACEL1710

    Appareils : HDH/HKD/DDM/FDM/CDM

    Easy viewing of system parameters, failure records and parameter adjustments.
  • Technical documentation

These products

may also be interested for you

CDM R410A

Cassette multisplit

Cassette multisplit

CDM R410A
See the product

Are you an individual ?

Airwell general public