DFM

Ducted high static pressure monosplit

Designed to fit into tight false ceiling

Its benefits

  • RCW08 remote control included
  • Low height (210 mm)
  • Alarm output and dry contact
  • Integrated condensate pump
  • Fresh air supply possible
  • G1 filter included
  • Constant flow control

The + "sustainable development":

    The + "user":

    • Invisible: blends into all types of interiors

    The + "installer":

    • Adapted to all types of ducts

    The + "technology":

    • Golden Fin (high corrosion resistance)
    • Self-adjusting static pressure auto-adaptative
    • Characteristics products
    • R410A fluid R410A fluid
      Golden fin treatment Golden fin treatment
      I Feel I Feel
      Night mode Night mode
      Programmable timer Programmable timer
      Auto Restart (Memory) Auto Restart (Memory)
      Remote control lock Remote control lock
      Error code via indoor unit Error code via indoor unit
      Self diagnostic Self diagnostic
      Integrated water pump Integrated water pump
      Left/right drain connection Left/right drain connection
      Alarm output Alarm output
      Dry contact on/off Dry contact on/off
      Unités intérieuresAW-DFM018-N11AW-DFM024-N11AW-DFM036-N11AW-DFM036T-N11AW-DFM048-N11AW-DFM060-N11
      Unités extérieures 1
      ~230V - 50Hz
      AW-YFFA018-H11 AW-YFFA024-H11 AW-YFFA036-H11
      Unités extérieures 3
      ~400V - 50Hz - N
      AW-YFFA036-H13 AW-YFFA048-H13 AW-YFFA060-H13
      Cooling
      Rated capacitykw5.587.9810.5410.8213.7315.12
      SEER / Energy label / E / E / D / C / D / E
      Operating limits°C18°/46° Dry bulb18°/46° Dry bulb18°/46° Dry bulb18°/46° Dry bulb18°/46° Dry bulb18°/46° Dry bulb
      Heating
      Rated capacitykW5.888.2411.812.1616.3917.71
      SCOP (average climate) / Energy label (average climate) / E / C / C / B / C / D
      Operating limits°C-7°/24° Bulbe se-7°/24° Bulbe se-7°/24° Bulbe se-7°/24° Bulbe se-7°/24° Bulbe se-7°/24° Bulbe se
      Indoor unit
      Sound power level (LS/MS/HS/SS)dB(A)39/42/4437/40/4340/44/4838/40/4741/45/4840/46/50
      Airflow (LS/MS/HS/SS)m³/h730/813/978964/1177/13581160/1383/18361149/1372/18041490/1850/21001490/1850/2400
      Code7SP0322067SP0322077SP0322127SP0322097SP0322107SP032211
      Energy label
      Outdoor unit
      Sound power level (LS/MS/HS/SS)m³/h
      Outline Dimensions (WxHxD)mm770x555x300845x702x363946x810x410946x810x410900x1170x350900x1170x350
      Net Weightkg36.5/39.752.7/56.179.5/85.374.4/78.997/10797/108
      Code 1~230V - 50 Hz 7SP063066 7SP063067 7SP063072
      Code 3~400V - 50 Hz 7SP063069 7SP063070 7SP063071
      Energy label
      Alimentation
      Phase/Tension/Frequency1P/230V/50Hz1P/230V/50Hz1P/230V/50Hz3P/N/400V/50Hz3P/N/400V/50Hz3P/N/400V/50Hz
      Power supply sideIndoorIndoorOutdoorOutdoorIndoorIndoor
      Power cable sectionmm²3x2.53x2.53x45x2.55x2.55x2.5
      Fuse rating am A163250  25 32 32 
      Electrical connectionsmm²3x2.5 + 2x1 + 2x0.753x2.5 + 2x1 + 2x0.23x1.5+ 3x1 + 2x0.23x1.5 + 3x15x2.5 + 3x15x2.5+ 3x1
      Liaison frigorifique
      Suction pipe diameterinches1/2”5/8”3/4”3/4”3/4”3/4”
      Liquid pipe diameterinches1/4”3/8”3/8”3/8”3/8”3/8”
      Max lengthm252530305050
      Max heightm151520203030
      Refrigerant / GWPR410A/2088R410A/2088R410A/2088R410A/2088R410A/2088R410A/2088
      Charge (5 m)kg1.51.82.52.853.33.2
      Additional chargeg/m151530303030
      Actions Request a quote Request a quote Request a quote Request a quote Request a quote Request a quote
    • Accessories and options
    • Wireless controller RC08C

      Wireless controller RC08C

      Réf. : 7ACEL1740

      Appareils : DDM/DFM

      Timer, eco mode, “Follow me” option, swing, technician mode, heating only mode.

      Wired single control RCW6

      Wired single control RCW6

      Réf. : 7ACEL1704

      Appareils : FFM/CFM/DFM

      Mode, fan speed, real time, timer, temperature, weekly timer and swing.

      Central controller RCW16

      Central controller RCW16

      Réf. : 7ACEL1707

      Appareils : FFM/CFM/DFM

      Controls up to 64 indoor units with individual setting failure codes indication, ON-OFF dry contact, last operation memory, ModBus.

      BMS gateway

      BMS gateway

      Réf. : 7ACEL1708

      Appareils : DDM/FDM/CDM/FFM/CFM/DFM

      Maximum 1024 units could be connected (16 gateways).