DDM R32

Ducted medium static pressure monosplit & multisplit

Designed to fit into tight false ceiling

Its benefits

  • 7ACEL1774 remote control included
  • Low height (200 mm)
  • Alarm output and dry contact
  • Integrated condensate pump
  • Fresh air supply possible
  • Multisplit compatible
  • R32/R410A compatible
  • Constant flow control

The + "sustainable development":

  • High energy class A++ (cooling mode)/A+ (heating mode)

The + "user":

  • Invisible: blends into all types of interiors
  • Quiet

The + "installer":

  • Suitable for long duct lengths (160 Pa)

The + "technology":

  • Golden Fin (high corrosion resistance)
  • Electronic expansion valve
  • Self-adjusting static pressure
  • Characteristics products
  • Hybrid House compatible Hybrid House compatible
    R32 fluid R32 fluid
    Flexy Match Flexy Match
    DC Inverter DC Inverter
    Electronic expansion valve Electronic expansion valve
    Golden fin treatment Golden fin treatment
    Air filter Air filter
    I Feel I Feel
    Night mode Night mode
    Programmable timer Programmable timer
    Auto Restart (Memory) Auto Restart (Memory)
    RT 2012 RT 2012
    Error code via indoor unit Error code via indoor unit
    Self diagnostic Self diagnostic
    Integrated water pump Integrated water pump
    Left/right drain connection Left/right drain connection
    Alarm output Alarm output
    Dry contact on/off Dry contact on/off
    Heating only mode Heating only mode
    Unités intérieuresAW-DDM012-N91AW-DDM018-N91AW-DDM048-N91
    Unités extérieures 1
    ~230V - 50Hz
    Unités extérieures 3
    ~400V - 50Hz - N
    Cooling
    Rated capacitykw3.52 (1.50-4.75)5.28 (1.49-5.69)14.07 (4.26-15.19)
    SEER / Energy label6.5/A++ / A++6.1/A++ / A++6.1/A++ / A++
    Operating limits°C-15°/50° Dry bulb-15°/50° Dry bulb-15°/50° Dry bulb
    Heating
    Rated capacitykW4.10 (0.97-5.63)5.86 (2.2-6.15)16.12 (3.7-18.02)
    SCOP (average climate) / Energy label (average climate)4.0/A+ / A+4.0/A+ / A+4.0/A+ / A+
    Operating limits°C-15°/24° Dry bulb-15°/24° Dry bulb-15°/24° Dry bulb
    Indoor unit
    Sound power level (LS/MS/HS/SS)dB(A)565968
    Airflow (LS/MS/HS/SS)m³/h300/480/600350/650/8801680/2040/2400
    Code7SP0330317SP0330327SP033035
    Energy label
    Outdoor unit
    Sound power level (LS/MS/HS/SS)m³/h626272
    Outline Dimensions (WxHxD)mm800x554x333800x554x333952x1333x415
    Net Weightkg34.7/37.533.7/36.6106.7/119.9
    Code 1~230V - 50 Hz
    Code 3~400V - 50 Hz
    Energy label
    Alimentation
    Phase/Tension/Frequency1P/220-240V/50Hz1P/220-240V/50Hz3P/380-410V/50Hz
    Power supply sideOutdoorOutdoorIndoor & Outdoor
    Power cable sectionmm²3x1.53x2.53x1.5+5x2.5
    Fuse rating am A16 1610+25
    Electrical connectionsmm²4x1.54x1.52x0.5
    Liaison frigorifique
    Suction pipe diameterinches3/8”1/2”5/8”
    Liquid pipe diameterinches1/4”1/4”3/8”
    Max lengthm253065
    Max heightm102030
    Refrigerant / GWPR32/675R32/675R32/675
    Charge (5 m)kg0.87 1.152.8
    Additional chargeg/m12 12 24
    Actions Request a quote Request a quote Request a quote
  • Related products
  • YDZC - Multisplit duo

    YDZC - Multisplit duo

    ...

  • Accessories and options
  • Wired single control RCW11

    Wired single control RCW11

    Réf. : 7ACEL1774

    Appareils : FDM/CDM

    Weekly timer, mode, fan speed, timer On/Off, “I Feel” function, temperature.

    Wireless controller RC08C

    Wireless controller RC08C

    Réf. : 7ACEL1740

    Appareils : DDM/DFM

    Timer, eco mode, “Follow me” option, swing, technician mode, heating only mode.

    Central controller RCW21

    Central controller RCW21

    Réf. : 7ACEL1777

    Appareils : DDM/FDM/CDM

    Central controller. Controls up to 64 indoor units with individual setting failure codes indication, On/Off dry contact, last operation memory.

    BMS gateway

    BMS gateway

    Réf. : 7ACEL1708

    Appareils : DDM/FDM/CDM/FFM/CFM/DFM

    Maximum 1024 units could be connected (16 gateways).

    Test tool

    Test tool

    Réf. : 7ACEL1710

    Appareils : HDH/HKD/DDM/FDM/CDM

    Easy viewing of system parameters, failure records and parameter adjustments.

    Insulated air duct plenum

    Réf. : 7ACVF0136

    Appareils : DDM

    3 ducts DN160. For DDM 12-18.
  • Technical documentation

These products

may also be interested for you

DDM R410A

Ducted medium static pressure monosplit & multisplit

Ducted medium static pressure monosplit & multisplit

DDM R410A
See the product

Are you an individual ?

Airwell general public