FCD

Floor ceiling monosplit

4 dimensional airflows for a maximum comfort

Its benefits

  • DC Inverter and sine wave compressor drive technology.
  • ”I Feel” function with precise room temperature control.
  • Available in 3PH from 10 kW.
  • Centralized controller up to 64 units (optional).
Easy to install product
Unique solutions
Trainings on our products
  • Characteristics products
  • DC Inverter DC Inverter
    Air filter Air filter
    Fresh air Fresh air
    I Feel I Feel
    Programmable timer Programmable timer
    Error code via indoor unit Error code via indoor unit
    Self diagnostic Self diagnostic
    Alarm output Alarm output
    Dry contact on/off Dry contact on/off
    Unités intérieuresAWSI-FCD018-N11AWSI-FCD024-N11AWSI-FCD036-N11AWSI-FCD036-N11AWSI-FCD048-N11AWSI-FCD060-N11
    Unités extérieures 1
    ~230V - 50Hz
    AWAU-YMD018-H11 AWAU-YMD024-H11 AWAU-YMD036-H11
    Unités extérieures 3
    ~400V - 50Hz - N
    AWAU-YMD036-H13 AWAU-YMD048-H13 AWAU-YMD060-H13
    Cooling
    Rated capacitykw5.1 (0.8-6.1)6.8 (1.2-8.2)10.5 (2.9-12.0)10.5 (2.9-12.0)14.0 (4.0-16.4)16.0 (5.0-18.1)
    SEER / Energy label6.5 / A++6.1 / A++6.3 / A++6.1 / A++6.1 / A++6.1 / A++
    Operating limits°C-15°/50° Dry bulb-15°/50° Dry bulb-15°/50° Dry bulb-15°/50° Dry bulb-15°/50° Dry bulb-15°/50° Dry bulb
    Heating
    Rated capacitykW5.6 (0.9-7.0)7.5 (1.2-8.6)11.0 (2.6-13.2)11.0 (2.6-13.2)16.0 (4.4-18.4)18.0 (5.3-20.5)
    SCOP (average climate) / Energy label (average climate)4.0 / A+4.0 / A+4.0 / A+4.0 / A+4.0 / A+4.0 / A+
    Operating limits°C-15°/24° Dry bulb-15°/24° Dry bulb-15°/24° Dry bulb-15°/24° Dry bulb-15°/24° Dry bulb-15°/24° Dry bulb
    Indoor unit
    Sound pressure level to 1 m (LS/MS/HS/SS)dB(A)38/41/4444/49/5243/49/5243/49/5246/51/5446/51/57
    Outline Dimensions (WxHxD)mm1068x675x2351068x675x2351650x675x2351650x675x2351650x675x2351650x675x235
    Net Weightkg25.82540.340.338.240.5
    Code7SP0122317SP0122327SP0122337SP0122337SP0122347SP012235
    Energy labelSee the labelSee the labelSee the labelSee the labelSee the labelSee the label
    Outdoor unit
    Sound pressure level to 1 m (LS/MS/HS/SS)dB(A)546061616363
    Outline Dimensions (WxHxD)mm800x554x333845x702x363946x810x410946x810x410952x1333x415952x1333x415
    Net Weightkg35.54967.278.9108.1112.8
    Code 1~230V - 50 Hz 7SP062892 7SP062893 7SP062895
    Code 3~400V - 50 Hz 7SP062896 7SP062899 7SP062900
    Energy labelSee the labelSee the labelSee the labelSee the labelSee the labelSee the label
    Alimentation
    Phase/Tension/Frequency1P/230V/50Hz1P/230V/50Hz1P/230V/50Hz3P/400V/50Hz3P/400V/50Hz3P/400V/50Hz
    Power supply sideIndoor & OutdoorIndoor & OutdoorIndoor & OutdoorIndoor & OutdoorIndoor & OutdoorIndoor & Outdoor
    Power cable sectionmm²3x1.0+3x2.53x1.0+3x2.53x1.0+3x4.03x1.0+5x2.53x1.0+5x2.53x1.0+5x2.5
    Fuse rating am A10+1610+2510+3010+2010+2510+25
    Electrical connectionsmm²2x0.52x0.52x0.52x0.52x0.52x0.5
    Liaison frigorifique
    Suction pipe diameterinches1/2”5/8”5/8”5/8”5/8”5/8”
    Liquid pipe diameterinches1/4”3/8”3/8”3/8”3/8”3/8”
    Max lengthm305065656565
    Max heightm202530303030
    Refrigerant / GWPR410A/2088R410A/2088R410A/2088R410A/2088R410A/2088R410A/2088
    Charge (5 m)kg1.781.953.23.244.3
    Additional chargeg/m153030303030
    Actions Request a quote Request a quote Request a quote Request a quote Request a quote Request a quote
  • Accessories and options
  • Wireless controller RC08C

    Wireless controller RC08C

    Réf. : 7ACEL1740

    Appareils : HRD/DID

    Timer, eco mode, “Follow me” option, swing, technician mode.

    Wired single control RCW6

    Wired single control RCW6

    Réf. : 7ACEL1704

    Appareils : DID/CCD/FCD

    Mode, fan speed, real time, timer, temperature, weekly timer, swing and “I Feel”.

    Wired single control RCW8

    Wired single control RCW8

    Réf. : 7ACEL1706

    Appareils : HKD/CCD/XBD/FCD

    Mode, fan speed, timer ON/OFF, temperature and swing.

    Central controller RCW16

    Central controller RCW16

    Réf. : 7ACEL1707

    Appareils : HRD/DID/CCD/FCD/FWDB

    Controls up to 64 indoor units with individual setting failure codes indication, ON-OFF dry contact, last operation memory, Modbus.

    BMS gateway

    BMS gateway

    Réf. : 7ACEL1708

    Appareils : DID/CCD/FCD/FWDB

    Maximum 1024 units could be connected (16 gateways).
  • Technical documentation

These products

may also be interested for you

FCD

Floor ceiling monosplit

Floor ceiling monosplit

FCD
See the product

PAC BT Monobloc

Low temperature air/water monobloc heat pump

Low temperature air/water monobloc heat pump

PAC BT Monobloc
See the product

DLSE+VAV

Ducted medium static pressure monosplit

Ducted medium static pressure monosplit

DLSE+VAV
See the product

EAV

Console

CBV

Cassette 600x600

Cassette 600x600

CBV
See the product

PAC BT

Low temperature monobloc heat pump

Low temperature monobloc heat pump

PAC BT
See the product

Are you an individual ?

Airwell general public