FDM R410A

Floor ceiling monosplit

4 dimensional airflow for maximum comfort

Its benefits

  • 7ACEL1740 remote control included
  • Alarm output and dry contact
  • Long air supply distance up to 11 m
  • 4D airflow

The + "sustainable development":

  • High energy class A++ (cooling mode)/A+ (heating mode)

The + "user":

  • Wide air distribution for large room volume

The + "installer":

  • Parameters can be read on the indoor unit

The + "technology":

  • High corrosion resistance with the Golden Fin
  • Electronic expansion valve
  • Characteristics products
  • R410A fluid R410A fluid
    Flexy Match Flexy Match
    DC Inverter DC Inverter
    Electronic expansion valve Electronic expansion valve
    Golden fin treatment Golden fin treatment
    Air filter Air filter
    Fresh air Fresh air
    I Feel I Feel
    Night mode Night mode
    Programmable timer Programmable timer
    Auto Restart (Memory) Auto Restart (Memory)
    Error code via indoor unit Error code via indoor unit
    Self diagnostic Self diagnostic
    Left/right drain connection Left/right drain connection
    Alarm output Alarm output
    Dry contact on/off Dry contact on/off
    Heating only mode Heating only mode
    Unités intérieuresAW-FDM018-N91AW-FDM024-N91AW-FDM036-N91AW-FDM036-N91AW-FDM048-N91AW-FDM060-N91
    Unités extérieures 1
    ~230V - 50Hz
    AWAU-YMD018-H11 AWAU-YMD024-H11 AWAU-YMD036-H11
    Unités extérieures 3
    ~400V - 50Hz - N
    AWAU-YMD036-H13 AWAU-YMD048-H13 AWAU-YMD060-H13
    Cooling
    Rated capacitykw5.1 (0.8-6.1)6.8 (1.2-8.2)10.5 (2.9-12.0)10.5 (2.9-12.0)14.0 (4.0-16.4)16.0 (5.0-18.1)
    SEER / Energy label6.5/A++ / A++6.1/A++ / A++6.3/A++ / A++6.1/A++ / A++6.1/A++ / A++6.1/A++ / A++
    Operating limits°C-15°/50° Dry bulb-15°/50° Dry bulb-15°/50° Dry bulb-15°/50° Dry bulb-15°/50° Dry bulb-15°/50° Dry bulb
    Heating
    Rated capacitykW5.6 (0.9-7.0)7.5 (1.2-8.6)11.0 (2.6-13.2)11.0 (2.6-13.2)16.0 (4.4-18.4)18.0 (5.3-20.5)
    SCOP (average climate) / Energy label (average climate)4.0/A+ / A+4.0/A+ / A+4.0/A+ / A+4.0/A+ / A+4.0/A+ / A+4.0/A+ / A+
    Operating limits°C-15°/24° Dry bulb-15°/24° Dry bulb-15°/24° Dry bulb-15°/24° Dry bulb-15°/24° Dry bulb-15°/24° Dry bulb
    Indoor unit
    Sound power level (LS/MS/HS/SS)dB(A)576363636669
    Airflow (LS/MS/HS/SS)m³/h700/800/900850/1050/11801400/1770/20501400/1770/20501400/1800/21001280/1660/2250
    Code7SP0122637SP0122647SP0122657SP0122657SP0122667SP012267
    Energy label
    Outdoor unit
    Sound power level (LS/MS/HS/SS)m³/h656567687275
    Outline Dimensions (WxHxD)mm800x554x333845x702x363946x810x410946x810x410952x1333x415952x1333x415
    Net Weightkg34.5/37.249/51.567.2/72.978.9/83.9108.1/121.2112.8/126
    Code 1~230V - 50 Hz 7SP062972 7SP062893 7SP062895
    Code 3~400V - 50 Hz 7SP062896 7SP062899 7SP062900
    Energy labelSee the labelSee the labelSee the labelSee the labelSee the labelSee the label
    Alimentation
    Phase/Tension/Frequency1P/230V/50Hz1P/230V/50Hz1P/230V/50Hz3P/400V/50Hz3P/400V/50Hz3P/400V/50Hz
    Power supply sideIndoor & OutdoorIndoor & OutdoorIndoor & OutdoorIndoor & OutdoorIndoor & OutdoorIndoor & Outdoor
    Power cable sectionmm²3x1.0+3x2.53x1.0+3x2.53x1.0+3x4.03x1.0+5x2.53x1.0+5x2.53x1.0+5x2.5
    Fuse rating am A10+1610+2510+3010+2010+2510+25
    Electrical connectionsmm²2x0.52x0.52x0.52x0.52x0.52x0.5
    Liaison frigorifique
    Suction pipe diameterinches1/2”5/8”5/8”5/8”5/8”5/8”
    Liquid pipe diameterinches1/4”3/8”3/8”3/8”3/8”3/8”
    Max lengthm305065656565
    Max heightm202530303030
    Refrigerant / GWPR410A/2088R410A/2088R410A/2088R410A/2088R410A/2088R410A/2088
    Charge (5 m)kg1.351.953.23.244.3
    Additional chargeg/m153030303030
    Actions Request a quote Request a quote Request a quote Request a quote Request a quote Request a quote
  • Accessories and options
  • Wireless controller RC08C

    Wireless controller RC08C

    Réf. : 7ACEL1740

    Appareils : DDM/DFM

    Timer, eco mode, “Follow me” option, swing, technician mode, heating only mode.

    Wired single control RCW11

    Wired single control RCW11

    Réf. : 7ACEL1774

    Appareils : FDM/CDM

    Weekly timer, mode, fan speed, timer On/Off, “I Feel” function, temperature.

    Central controller RCW21

    Central controller RCW21

    Réf. : 7ACEL1777

    Appareils : DDM/FDM/CDM

    Central controller. Controls up to 64 indoor units with individual setting failure codes indication, On/Off dry contact, last operation memory.

    BMS gateway

    BMS gateway

    Réf. : 7ACEL1708

    Appareils : DDM/FDM/CDM/FFM/CFM/DFM

    Maximum 1024 units could be connected (16 gateways).

    Test tool

    Test tool

    Réf. : 7ACEL1710

    Appareils : HDH/HKD/DDM/FDM/CDM

    Easy viewing of system parameters, failure records and parameter adjustments.

    Water pump Mini Flowatch MF2

    Water pump Mini Flowatch MF2

    Réf. : 7ACTL0517

    Appareils : FDM/FWDB

    Evacuate condensates from indoor units.
  • Technical documentation

These products

may also be interested for you

FFM

Floor ceiling monosplit

Floor ceiling monosplit

FFM
See the product

FDM R32

Floor ceiling monosplit

Floor ceiling monosplit

FDM R32
See the product

Are you an individual ?

Airwell general public