FFM

Floor ceiling monosplit

4 dimensional airflow for maximum comfort

Its benefits

  • 7ACEL1740 remote control included
  • Alarm output and dry contact
  • Long air supply distance up to 11 m
  • G1 filter included
  • 4D airflow

The + "sustainable development":

    The + "user":

    • Choice of installation options: wall or ceiling-mounted

    The + "installer":

    • Parameters can be read on the indoor unit

    The + "technology":

    • High corrosion resistance with the Golden Fin
    • Characteristics products
    • R410A fluid R410A fluid
      Golden fin treatment Golden fin treatment
      Air filter Air filter
      Fresh air Fresh air
      I Feel I Feel
      Night mode Night mode
      Programmable timer Programmable timer
      Auto Restart (Memory) Auto Restart (Memory)
      Remote control lock Remote control lock
      Error code via indoor unit Error code via indoor unit
      Self diagnostic Self diagnostic
      Left/right drain connection Left/right drain connection
      Auxiliary heater Auxiliary heater
      Technician test mode Technician test mode
      Unités intérieuresAW-FFM018-N11AW-FFM024-N11AW-FFM036-N11AW-FFM036T-N11AW-FFM048-N11AW-FFM060-N11
      Unités extérieures 1
      ~230V - 50Hz
      AW-YFFA018-H11 AW-YFFA024-H11 AW-YFFA036-H11
      Unités extérieures 3
      ~400V - 50Hz - N
      AW-YFFA036-H13 AW-YFFM048-H13 AW-YFFA060-H13
      Cooling
      Rated capacitykw5.816.899.9810.4813.0114.54
      SEER / Energy label / E / D / C / C / D / E
      Operating limits°C18°/46° Dry bulb18°/46° Dry bulb18°/46° Dry bulb18°/46° Dry bulb18°/46° Dry bulb18°/46° Dry bulb
      Heating
      Rated capacitykW5.847.9211.5311.5113.7416.67
      SCOP (average climate) / Energy label (average climate) / C / D / E / D / D / D
      Operating limits°C-7°/24° Dry bulb-7°/24° Dry bulb-7°/24° Dry bulb-7°/24° Dry bulb-7°/24° Dry bulb-7°/24° Dry bulb
      Indoor unit
      Sound power level (LS/MS/HS/SS)dB(A)42/46/5143/48/5345/49/5445/48/5345/49/5448/51/55
      Airflow (LS/MS/HS/SS)m³/h775/932/1152867/1038/12511302/1533/18211331/1536/181916111636/1846/2267
      Code7SP0122687SP0122697SP0122737SP0122707SP0122717SP012272
      Energy label
      Outdoor unit
      Sound power level (LS/MS/HS/SS)m³/h
      Outline Dimensions (WxHxD)mm770x555x300845x702x363946x810x410946x810x410900x1170x350900x1170x350
      Net Weightkg36.5/39.752.7/56.179.5/85.374.4/78.993.2/10597/108
      Code 1~230V - 50 Hz 7SP063066 7SP063067 7SP063072
      Code 3~400V - 50 Hz 7SP063069 7SP063073 7SP063071
      Energy label
      Alimentation
      Phase/Tension/Frequency1P/230V/50Hz1P/230V/50Hz1P/230V/50Hz3P/N/400V/50Hz3P/N/400V/50Hz3P/N/400V/50Hz
      Power supply sideIndoorIndoorOutdoorOutdoorIndoorIndoor
      Power cable sectionmm²3x2.53x2.53x45x2.55x2.55x2.5
      Fuse rating am A163250  25 32 32 
      Electrical connectionsmm²3x2.5 + 2x1 + 2x0.753x2.5 + 2x1 + 2x0.23x1.5 + 3x1 + 2x0.23x1.5 + 3x15x2.5 + 3x15x2.5+ 3x1
      Liaison frigorifique
      Suction pipe diameterinches1/2”5/8”3/4”3/4”3/4”3/4”
      Liquid pipe diameterinches1/4”3/8”3/8”3/8”3/8”3/8”
      Max lengthm252530305050
      Max heightm151520203030
      Refrigerant / GWPR410A/2088R410A/2088R410A/2088R410A/2088R410A/2088R410A/2088
      Charge (5 m)kg1.51.82.52.853.253.2
      Additional chargeg/m
      Actions Request a quote Request a quote Request a quote Request a quote Request a quote Request a quote
    • Accessories and options
    • Wireless controller RC08C

      Wireless controller RC08C

      Réf. : 7ACEL1740

      Appareils : DDM/DFM

      Timer, eco mode, “Follow me” option, swing, technician mode, heating only mode.

      Wired single control RCW6

      Wired single control RCW6

      Réf. : 7ACEL1704

      Appareils : FFM/CFM/DFM

      Mode, fan speed, real time, timer, temperature, weekly timer and swing.

      Wired single control RCW8

      Wired single control RCW8

      Réf. : 7ACEL1706

      Appareils : HKD/XDM/FFM/CFM

      Mode, fan speed, timer On/Off, temperature and swing.

      Central controller RCW16

      Central controller RCW16

      Réf. : 7ACEL1707

      Appareils : FFM/CFM/DFM

      Controls up to 64 indoor units with individual setting failure codes indication, ON-OFF dry contact, last operation memory, ModBus.

      BMS gateway

      BMS gateway

      Réf. : 7ACEL1708

      Appareils : DDM/FDM/CDM/FFM/CFM/DFM

      Maximum 1024 units could be connected (16 gateways).
    • Technical documentation

    These products

    may also be interested for you

    FDM R410A

    Floor ceiling monosplit

    Floor ceiling monosplit

    FDM R410A
    See the product

    FDM R32

    Floor ceiling monosplit

    Floor ceiling monosplit

    FDM R32
    See the product

    Are you an individual ?

    Airwell general public