FWDB

Floor ceiling monosplit for low temperature rooms

Ideal solution for low temperature room

Its benefits

  • Cooling & heating operation mode.
  • DC Inverter and sine wave compressor drive technology.
  • “I Feel” function with precise room temperature control.
  • Fuzzy logic to control compressor by outdoor fan and electronic expansion valve in extreme low operation temperature.
  • Possibility to reverse dry contact: normally open/normally closed.
Easy to install product
Unique solutions
Trainings on our products
  • Characteristics products
  • DC Inverter DC Inverter
    Air filter Air filter
    Fresh air Fresh air
    Programmable timer Programmable timer
    Error code via indoor unit Error code via indoor unit
    Self diagnostic Self diagnostic
    Alarm output Alarm output
    Dry contact on/off Dry contact on/off
    Unités intérieuresAWSI-FWDB018-N11AWSI-FWDB024-N11
    Unités extérieures 1
    ~230V - 50Hz
    AWAU-YMDB018-H11 AWAU-YMDB024-H11
    Unités extérieures 3
    ~400V - 50Hz - N
    Cooling
    Rated capacitykw5.1 (0.8-6.1)6.8 (1.2-8.2)
    SEER / Energy label6.5 / A++6.1 / A++
    Operating limits°C-10°/50° Dry bulb-10°/50° Dry bulb
    Heating
    Rated capacitykW5.6 (0.9-7.0)7.5 (1.2-8.6)
    SCOP (average climate) / Energy label (average climate)4.0 / A+4.0 / A+
    Operating limits°C-15°/24° Dry bulb-15°/24° Dry bulb
    Indoor unit
    Sound pressure level to 1 m (LS/MS/HS/SS)dB(A)38/41/4444/49/52
    Outline Dimensions (WxHxD)mm1068x235x6751068x235x675
    Net Weightkg25.825
    Code7SP0122467SP012247
    Energy labelSee the labelSee the label
    Outdoor unit
    Sound pressure level to 1 m (LS/MS/HS/SS)dB(A)5460
    Outline Dimensions (WxHxD)mm800x554x333845x702x363
    Net Weightkg35.549
    Code 1~230V - 50 Hz 7SP062924 7SP062925
    Code 3~400V - 50 Hz
    Energy label
    Alimentation
    Phase/Tension/Frequency1P/230V/50Hz1P/230V/50Hz
    Power supply sideIndoor & OutdoorIndoor & Outdoor
    Power cable sectionmm²3x1.0+3x2.53x1.0+3x2.5
    Fuse rating am A10+1610+25
    Electrical connectionsmm²2x0.52x0.5
    Liaison frigorifique
    Suction pipe diameterinches1/2”5/8”
    Liquid pipe diameterinches1/4”3/8”
    Max lengthm3050
    Max heightm2025
    Refrigerant / GWPR410A/2088R410A/2088
    Charge (5 m)kg1.781.95
    Additional chargeg/m1530
    Actions Request a quote Request a quote
  • Accessories and options
  • Central controller RCW16

    Central controller RCW16

    Réf. : 7ACEL1707

    Appareils : HRD/DID/CCD/FCD/FWDB

    Controls up to 64 indoor units with individual setting failure codes indication, ON-OFF dry contact, last operation memory, Modbus.

    BMS gateway

    BMS gateway

    Réf. : 7ACEL1708

    Appareils : DID/CCD/FCD/FWDB

    Maximum 1024 units could be connected (16 gateways).
  • Technical documentation

These products

may also be interested for you

TDF

Ducted thermodynamic water heater

Ducted thermodynamic water heater

TDF
See the product

DBV

Ducted medium static pressure

Ducted medium static pressure

DBV
See the product

HAN

Rooftop unit

Rooftop unit

HAN
See the product

HKD

High wall monosplit & multisplit

High wall monosplit & multisplit

HKD
See the product

WFD

Window

XBD

Console dual flow monosplit & multisplit

Console dual flow monosplit & multisplit

XBD
See the product

Are you an individual ?

Airwell general public