PAC HT Monobloc

High temperature monobloc heat pump

Its benefits

  • Ideal for renovations (HT) as well as for new construction (LT).
  • Constant operation at +65°C with -20°C outdoors.
  • 6 to 18 kW of heating over 3 models.
  • A single refrigerant fluid: R407C.
  • Possibility of installing heat pumps in cascade.
  • Patents Airwell: two-stage compression and oil management system.
  • “Plug and play” system: easy for boiler replacement.
  • Large digital display with diagnosis aid.
  • Heating only.
Easy to install product
Unique solutions
Trainings on our products
  • Characteristics products
  • Super quiet Super quiet
    Unités intérieuresPAC HT 12-6PAC HT 14-7PAC HT 12-6PAC HT 14-7PAC HT 18-9
    Unités extérieures 1
    ~230V - 50Hz
    Unités extérieures 3
    ~400V - 50Hz - N
    Cooling
    Rated capacitykw
    SEER / Energy label / / / / /
    Operating limits°C
    Heating
    Rated capacitykW6.307.406.307.408.98
    SCOP (average climate) / Energy label (average climate)3.79 / A+3.85 / A+3.79 / A+3.85 / A+3.87 / A++
    Operating limits°C-20-20-20-20-20
    Indoor unit
    Sound pressure level to 1 m (LS/MS/HS/SS)dB(A)
    Outline Dimensions (WxHxD)mm
    Net Weightkg
    Code7OG0130117OG0130137OG0130127OG0130147OG013015
    Energy label
    Outdoor unit
    Sound pressure level to 1 m (LS/MS/HS/SS)dB(A)
    Outline Dimensions (WxHxD)mm1456.60 x 1308 x 5161456.60 x 1308 x 5161456.60 x 1308 x 5161456.60 x 1308 x 5161456.60 x 1308 x 516
    Net Weightkg
    Code 1~230V - 50 Hz
    Code 3~400V - 50 Hz
    Energy labelSee the labelSee the labelSee the labelSee the labelSee the label
    Alimentation
    Liaison frigorifique
    Actions Request a quote Request a quote Request a quote Request a quote Request a quote
  • Accessories and options
  • Shut-off valve with pressure tap

    Réf. : 7ACFH0423

    Control valve

    Settling filter (pot)

    Settling filter (pot)

    Réf. : 7ACFH0666

    Appareils : All Heat Pumps

    Protect the heat pump from sludging and preserve optimum thermal exchange.

    Water filter

    Réf. : 7ACFH0278

    Protect the heat pump from sludging and preserve optimum thermal exchange.

    Buffer tank 140 L

    Buffer tank 140 L

    Réf. : 7ACFH0663

    Appareils : All Heat Pumps

    It protects the heat pump against short cycles that can reduce the useful life of the compressors and improves operation during defrosting phases.

    Three-way valve

    Three-way valve

    Réf. : 7ACFH0543

    Three-way valve alone for domestic hot water management or boiler back-up

    300 L domestic hot water tank kit

    300 L domestic hot water tank kit

    Réf. : 7ACFH0662

    Appareils : PAC BT MB

    Optimised with the operation of the heat pump:
    - Programmable anti-legionella function.
    - Management of the three-way valve / circulator pump couple.
    - 3.1 m² exchange surface.

    Kit for electrical DHW tank - Top outlet

    Kit for electrical DHW tank - Top outlet

    Réf. : 7ACFH0789

    Plate exchanger and circulator pump kit for domestic hot water, top outlet (sensor supplied for installation in a thimble)

    Kit for electrical DHW tank - Bottom outlet

    Kit for electrical DHW tank - Bottom outlet

    Réf. : 7ACFH0801

    Plate exchanger and circulator pump kit for domestic hot water, bottom outlet (sensor supplied and installed)

    On-line electric heater - 2/4/6 kW

    On-line electric heater - 2/4/6 kW

    Réf. : 7ACFH0665

    Installation inside the building, offers two power stages (2 and 4 kW, or 6 kW in total). Provides extra heating when the heating demand is greater than the capacity of the heat pump.

    Hydraulic connection kit without three-way valve

    Hydraulic connection kit without three-way valve

    Réf. : 7ACFH0491

    For connecting to the boiler, available alone or in a complete kit with the three-way valve. Made up of a set of assembled pipes and valves, a set of connectors with sphericalconical seat.

    Wired ambient thermostat

    Wired ambient thermostat

    Réf. : 7ACEL1592

    - Adjustment of ambient temperature
    - Daily or weekly programming
    - Holiday programming, no-frost mode

    Remote wireless ambient thermostat unit

    Remote wireless ambient thermostat unit

    Réf. : 7ACEL1593

    - Adjustment of ambient temperature
    - Daily or weekly programming
    - Holiday programming, no-frost mode

    Shock-absorbing support feet

    Shock-absorbing support feet

    Réf. : 7ACTL0472

    Raise the heat pump by 10 cm, allow the evacuation of condensates and defrosting water.

    Three-phase starting intensity limiter

    Réf. : 7ACEL1535

    Standard on single-phase
  • Technical documentation

These products

may also be interested for you

HDM

High wall monosplit & multisplit

High wall monosplit & multisplit

HDM
See the product

FAV

Floor ceiling

Floor ceiling

FAV
See the product

EAV

Console

HKD

High wall monosplit & multisplit

High wall monosplit & multisplit

HKD
See the product

WFD

Window

SXT (TELECOM)

Floor ceiling

Floor ceiling

SXT (TELECOM)
See the product

Are you an individual ?

Airwell general public