Its benefits

  • Available with R32 from 4 to 10 kW and R410A from 12 to 16 kW
  • Refrigerant connections; no need for antifreeze protection
  • Compact indoor and outdoor unit
  • Compatible with all types of emitter

The + "sustainable development":

  • High energy class A+++

The + "user":

  • Compatible with all emitters
  • Great flexibility of use
  • Perfect for replacing an oil or gas burner

The + "installer":

  • Customisable water program, allowing the entire heating circuit to be managed using the many available connections

The + "technology":

  • Operates at outdoor temperatures down to -25 °C
  • HP Keymark certified
  • Characteristics products
  • Hybrid House compatible Hybrid House compatible
    Keymark Certification Keymark Certification
    Week timer Week timer
    Unit on output Unit on output
    Heating mode operational down to -25°C outdoors Heating mode operational down to -25°C outdoors
    High temperature up to 60 °c High temperature up to 60 °c
    Domestic hot water Domestic hot water
    Floor heating Floor heating
    High-temperature radiator High-temperature radiator
    Low-temperature radiator Low-temperature radiator
    Boiler replacement Boiler replacement
    Boiler back-up Boiler back-up
    Lois d’eau Lois d’eau
    CEE CEE
    Unités intérieuresAW-YHPS04-H91AW-YHPS06-H91AW-YHPS08-H91AW-YHPS10-H91PAC-BT-UE-12kW-H11PAC-BT-UE-12kW-H13PAC-BT-UE-14kW-H11PAC-BT-UE-14kW-H13PAC-BT-UE-16kW-H11PAC-BT-UE-16kW-H13
    Unités extérieures 1
    ~230V - 50Hz
    Unités extérieures 3
    ~400V - 50Hz - N
    Cooling
    Rated capacitykw
    SEER / Energy label / / / / / / / / / /
    Operating limits°C-5/53-5/53-5/53-5/53-5/46-5/46-5/46-5/46-5/46-5/53
    Heating
    Pdesignh (average climate)kW
    SCOP (average climate) / Energy label (average climate) / / / / / / / / / /
    Operating limits°C-25/36-25/36-25/36-25/36-20/35-20/35-20/35-20/35-20/35-25/36
    Indoor unit
    Sound pressure level to 1 m (LS/MS/HS/SS)dB(A)
    Outline Dimensions (WxHxD)mm400x850x427400x850x427400x850x427400x850x427462x700x316462x700x316462x700x316462x700x316462x700x316462x700x316
    Net Weightkg47/5347/5347/5347/5350/5150/5150/5150/5150/5150/51
    Code7HP0610607HP0610617HP0610627HP0610637HP0610307HP0610297HP0610327HP0610317HP0610347HP061033
    Energy label
    Outdoor unit
    Sound pressure level to 1 m (LS/MS/HS/SS)dB(A)
    Outline Dimensions (WxHxD)mm960x860x380960x860x3801075x965x3951075x965x395900x1327x400900x1327x400900x1327x400900x1327x400900x1327x400900x1327x400
    Net Weightkg57/6857/6867/7967/7999/112115/12699/112115/12699/112115/126
    Code 1~230V - 50 Hz
    Code 3~400V - 50 Hz
    Energy labelSee the labelSee the labelSee the labelSee the labelSee the labelSee the labelSee the labelSee the labelSee the labelSee the label
    Alimentation
    Phase/Tension/Frequency1P/220-240V/50Hz1P/220-240V/50Hz1P/220-240V/50Hz1P/220-240V/50Hz1P/220-240V/50Hz3P/380-415V/50Hz1P/220-240V/50Hz3P/380-415V/50Hz1P/220-240V/50Hz3P/380-415V/50Hz
    Power supply side
    Power cable sectionmm²
    Fuse rating am A
    Electrical connectionsmm²
    Liaison frigorifique
    Suction pipe diameterinches
    Liquid pipe diameterinches1/4”-5/8”1/4”-5/8”3/8”-5/8”3/8”-5/8”3/8”-5/8”3/8”-5/8”3/8”-5/8”3/8”-5/8”3/8”-5/8”3/8”-5/8”
    Max lengthm
    Max heightm
    Refrigerant / GWPR32/675R32/675R32/675R32/675R410A/2088R410A/2088R410A/2088R410A/2088R410A/2088R410A/2088
    Charge (5 m)kg1.551.551.651.653.94.23.94.23.94.2
    Additional chargeg/m20203838545454545454
    Actions Request a quote Request a quote Request a quote Request a quote Request a quote Request a quote Request a quote Request a quote Request a quote Request a quote
  • Accessories and options
  • Settling filter (pot)

    Settling filter (pot)

    Réf. : 7ACFH0666

    Appareils : All Heat Pumps

    Protect the heat pump from sludging and preserve optimum thermal exchange.

    Floor support rubber recycled (pair) Length: 1 000 mm

    Floor support rubber recycled (pair) Length: 1 000 mm

    Réf. : 7ACTL0510

    Appareils : All Heat Pumps

    Necessary for a professional installation.

    Electrical complement kit 2/4/6 kW mono PAC BT (recommended)

    Electrical complement kit 2/4/6 kW mono PAC BT (recommended)

    Réf. : 7ACFH0825

    Appareils : WELLEA SPLIT/WELLEA WT

    Allows to ensure additional heating via electrical resistance.

    Boiler backup kit PAC BT

    Boiler backup kit PAC BT

    Réf. : 7ACEL1757

    Appareils : WELLEA SPLIT/WELLEA WT

    Allows to connect a boiler (fuel, gas, wood…).

    Auxiliary condensate collection tray

    Réf. : 7ACFH0830

    Appareils : WELLEA SPLIT/WELLEA WT

    Complementary condensate tray, to increase the maximum condensate recovery volume.

    RCW15 Thermostat PAC BT (power supply mandatory)

    RCW15 Thermostat PAC BT (power supply mandatory)

    Réf. : 7ACEL1732

    Appareils : WELLEA SPLIT/WELLEA WT

    Temperature and humidity thermostat / Remote keyboard / weekly timer.

    Power supply for RCW15

    Réf. : 7ACEL1733

    Appareils : WELLEA SPLIT/WELLEA WT

    Power supply kit for RCW15.

    300L DHW tank

    Réf. : 7ACFH0834

    Appareils : WELLEA SPLIT

    Standard DHW tank (300L).

    500L DHW tank

    Réf. : 7ACFH0835

    Appareils : WELLEA SPLIT

    Standard DHW tank (500L).
  • Technical documentation

These products

may also be interested for you

Airflow 2020

Thermodynamic CMV dual flow

Thermodynamic CMV dual flow

Airflow 2020
See the product

FFM

Floor ceiling monosplit

Floor ceiling monosplit

FFM
See the product

TDF

Thermodynamic water heater

Thermodynamic water heater

TDF
See the product

DDV

Ducted low static pressure

Ducted low static pressure

DDV
See the product

DFM

Ducted high static pressure monosplit

Ducted high static pressure monosplit

DFM
See the product

HKD R32

High wall monosplit & multisplit

High wall monosplit & multisplit

HKD R32
See the product