Wellea WT

Split heat pump R32 with DHW tank included

Heat pump with DHW tank included - Solar energy possible

Its benefits

  • Available with R32 from
  • 4 to 10 kW and R410A from12 to 16 kW
  • Refrigerant connections; no need for antifreeze protection
  • Compact outdoor unit
  • Compatible with all types of emitter
  • Hot water tank included (190L or 280L)

The + "sustainable development":

  • High energy class A+++

The + "user":

  • Compatible with all emitters
  • Great flexibility of use
  • Perfect for replacing an oil or gas burner
  • Integrated hot water tank

The + "installer":

  • Customisable water program, allowing the entire heating circuit to be managed using the many available connections

The + "technology":

  • Operates at outdoor temperatures down to -25 °C
  • HP Keymark certified
  • Characteristics products
  • Hybrid House compatible Hybrid House compatible
    Keymark Certification Keymark Certification
    Week timer Week timer
    Heating mode operational down to -25°C outdoors Heating mode operational down to -25°C outdoors
    High temperature up to 60 °c High temperature up to 60 °c
    Domestic hot water Domestic hot water
    Floor heating Floor heating
    High-temperature radiator High-temperature radiator
    Low-temperature radiator Low-temperature radiator
    Boiler replacement Boiler replacement
    Boiler back-up Boiler back-up
    Lois d’eau Lois d’eau
    CEE CEE
    Unités intérieuresAW-YHPS04-H91AW-YHPS06-H91AW-YHPS08-H91AW-YHPS10-H91PAC-BT-UE-12kW-H11PAC-BT-UE-12kW-H13PAC-BT-UE-14kW-H11PAC-BT-UE-14kW-H13PAC-BT-UE-16kW-H11PAC-BT-UE-16kW-H13
    Unités extérieures 1
    ~230V - 50Hz
    Unités extérieures 3
    ~400V - 50Hz - N
    Cooling
    Rated capacitykw
    SEER / Energy label / / / / / / / / / /
    Operating limits°C-5/53-5/53-5/53-5/46-5/46-5/46-5/46-5/46-5/46-5/46
    Heating
    Pdesignh (average climate)kW
    SCOP (average climate) / Energy label (average climate) / / / / / / / / / /
    Operating limits°C-25/36-25/36-25/36-20/35-20/35-20/35-20/35-20/35-20/35-20/35
    Indoor unit
    Sound pressure level to 1 m (LS/MS/HS/SS)dB(A)
    Outline Dimensions (WxHxD)mm600x1774x610600x1774x610600x1774x610600x1774x610600x2040x800600x2040x800600x2040x800600x2040x800600x2040x800600x2040x800
    Net Weightkg167/185167/185167/185167/185190/200190/200190/200190/200190/200190/200
    Code7HP0610267HP0610277HP0610287HP0610307HP0610297HP0610327HP0610317HP0610347HP0610337OG013011
    Energy label
    Outdoor unit
    Sound pressure level to 1 m (LS/MS/HS/SS)dB(A)
    Outline Dimensions (WxHxD)mm960x860x380960x860x3801075x965x3951075x965x395900x1327x400900x1327x400900x1327x400900x1327x400900x1327x400900x1327x400
    Net Weightkg57/6857/6867/7967/7999/112115/12699/112115/12699/112115/126
    Code 1~230V - 50 Hz
    Code 3~400V - 50 Hz
    Energy labelSee the labelSee the labelSee the labelSee the labelSee the labelSee the labelSee the labelSee the labelSee the labelSee the label
    Alimentation
    Phase/Tension/Frequency1P/220-240V/50Hz1P/220-240V/50Hz1P/220-240V/50Hz1P/220-240V/50Hz1P/220-240V/50Hz3P/380-415V/50Hz1P/220-240V/50Hz3P/380-415V/50Hz1P/220-240V/50Hz3P/380-415V/50Hz
    Power supply side
    Power cable sectionmm²
    Fuse rating am A11.311.316.716.731.1932.31135.111.5
    Electrical connectionsmm²
    Liaison frigorifique
    Suction pipe diameterinches
    Liquid pipe diameterinches1/4 - 5/81/4 - 5/83/8 - 5/83/8 - 5/83/8 - 5/83/8 - 5/83/8 - 5/83/8 - 5/83/8 - 5/83/8 - 5/8
    Max lengthm
    Max heightm
    Refrigerant / GWPR32/675R32/675R32/675R32/675R410A/2088R410A/2088R410A/2088R410A/2088R410A/2088R410A/2088
    Charge (5 m)kg1.551.551.651.653.94.23.94.23.94.2
    Additional chargeg/m20203838545454545454
    Actions Request a quote Request a quote Request a quote Request a quote Request a quote Request a quote Request a quote Request a quote Request a quote Request a quote
  • Accessories and options
  • Settling filter (pot)

    Settling filter (pot)

    Réf. : 7ACFH0666

    Appareils : All Heat Pumps

    Protect the heat pump from sludging and preserve optimum thermal exchange.

    Floor support rubber recycled (pair) Length: 1 000 mm

    Floor support rubber recycled (pair) Length: 1 000 mm

    Réf. : 7ACTL0510

    Appareils : All Heat Pumps

    Necessary for a professional installation.

    8 liters expansion vessel kit (for DHW Version)

    Réf. : 7ACFH0831

    Appareils : WELLEA WT

    Safety element for compensating variations of water volume.

    Buffer tank 140 L

    Réf. : 7ACFH0663

    Appareils : All Heat Pumps

    It protects the heat pump against short cycles that can reduce the useful life of the compressors and improves operation during defrosting phases.

    Electrical complement kit 2/4/6 kW mono PAC BT (recommended)

    Electrical complement kit 2/4/6 kW mono PAC BT (recommended)

    Réf. : 7ACFH0825

    Appareils : WELLEA SPLIT/WELLEA WT

    Allows to ensure additional heating via electrical resistance.

    Boiler backup kit PAC BT

    Boiler backup kit PAC BT

    Réf. : 7ACEL1757

    Appareils : WELLEA SPLIT/WELLEA WT

    Allows to connect a boiler (fuel, gas, wood…).

    Auxiliary condensate collection tray

    Réf. : 7ACFH0830

    Appareils : WELLEA SPLIT/WELLEA WT

    Complementary condensate tray, to increase the maximum condensate recovery volume.

    RCW15 Thermostat PAC BT (power supply mandatory)

    RCW15 Thermostat PAC BT (power supply mandatory)

    Réf. : 7ACEL1732

    Appareils : WELLEA SPLIT/WELLEA WT

    Temperature and humidity thermostat / Remote keyboard / weekly timer.

    Power supply for RCW15

    Réf. : 7ACEL1733

    Appareils : WELLEA SPLIT/WELLEA WT

    Power supply kit for RCW15.

    Kit bi-zone 1 temperature PAC BT

    Réf. : 7ACFH0826

    Appareils : WELLEA WT

    Allows to manage two different zones with the same temperature.

    Kit bi-zone 2 temperatures PAC BT

    Réf. : 7ACFH0827

    Appareils : WELLEA WT

    Allows to manage two different zones with two temperatures.

    Auxiliary DHW tank 280L PAC BT

    Auxiliary DHW tank 280L PAC BT

    Réf. : 7ACEL1749

    Appareils : WELLEA WT

    Allows to increase the tank capacity of DHW.

    500L DHW tank with coil for solar applications

    Réf. : 7ACFH0833

    Appareils : WELLEA SPLIT/WELLEA WT

    DHW tank with coil for solar applications (500L).

    Kit bi-zone 1 temperature PAC BT

    Réf. : 7ACFH0823

    Appareils : WELLEA SPLIT

    Allows to manage two different zones with the same temperature.

    Kit bi-zone 2 temperatures PAC BT

    Réf. : 7ACFH0824

    Appareils : WELLEA SPLIT

    Allows to manage two different zones with two temperatures.

    300L DHW tank with coil for solar applications

    Réf. : 7ACFH0832

    Appareils : WELLEA SPLIT/WELLEA WT

    DHW tank with coil for solar applications (300L).

    300L DHW tank

    Réf. : 7ACFH0834

    Appareils : WELLEA SPLIT

    Standard DHW tank (300L).

    500L DHW tank

    Réf. : 7ACFH0835

    Appareils : WELLEA SPLIT

    Standard DHW tank (500L).
  • Technical documentation

These products

may also be interested for you

XAM

Vertical air cabinet

Vertical air cabinet

XAM
See the product

DDB R410A

Ducted high static pressure monosplit

Ducted high static pressure monosplit

DDB R410A
See the product

DFO

Water loop heat pump

Water loop heat pump

DFO
See the product

DDV

Ducted low static pressure

Ducted low static pressure

DDV
See the product

CBV

Cassette 600x600

Cassette 600x600

CBV
See the product

HKD R32

High wall monosplit & multisplit

High wall monosplit & multisplit

HKD R32
See the product

Are you an individual ?

Airwell general public