Its benefits

  • DC Inverter scroll compressor
  • Wide capacity range
  • Wide temperature range (-23/+50 °C)
  • Very small footprint: 0.97 m²

The + "sustainable development":

  • Low consumption and optimised regulation for greater energy savings

The + "user":

  • Capacity range from 8 to 72 HP
  • Large choice of indoor units

The + "installer":

  • Up to 1000 m of refrigeration network and 110 m of height difference
  • Access to all parameters via the HMI for easier commissioning and maintenance

The + "technology":

  • Anti-corrosion treatment
  • Up to 64 indoor units
  • Performance certified by Eurovent
  • Characteristics products
  • R410A fluid R410A fluid
    DC Inverter DC Inverter
    Self diagnostic Self diagnostic
    BMS Compatible BMS Compatible
    Service monitor tool Service monitor tool
    Unités intérieuresAWAU-YDV400-H13AWAU-YDV450-H13AWAU-YDV504-H13AWAU-YDV560-H13AWAU-YDV680-H13
    Unités extérieures 1
    ~230V - 50Hz
    Unités extérieures 3
    ~400V - 50Hz - N
    Cooling
    Rated capacitykw404550.45668
    SEER / Energy label / / / / /
    Operating limits°C-5°/50°-5°/50°-5°/50°-5°/50°-5°/50°
    Heating
    Rated capacitykW455056.56373
    SCOP (average climate) / Energy label (average climate) / / / / /
    Operating limits°C-23°/21°-23°/21°-23°/21°-23°/21°-23°/21°
    Indoor unit
    Sound power level (LS/MS/HS/SS)dB(A)
    Airflow (LS/MS/HS/SS)m³/h
    Code7SP14H0327SP14H0337SP14H0347SP14H0357SP14H037
    Energy label
    Outdoor unit
    Sound power level (LS/MS/HS/SS)m³/h7677797980
    Outline Dimensions (WxHxD)mm1350x1690x7201350x1690x7201350x2048x7201350x2048x7201350x2048x720
    Net Weightkg279/304321/346335/360335/360359/384
    Code 1~230V - 50 Hz
    Code 3~400V - 50 Hz
    Energy labelSee the labelSee the labelSee the labelSee the labelSee the label
    Alimentation
    Phase/Tension/Frequency3P/380-400V/50-60Hz/N3P/380-400V/50-60Hz/N3P/380-400V/50-60Hz/N3P/380-400V/50-60Hz/N3P/380-400V/50-60Hz/N
    Power supply side
    Power cable sectionmm²
    Fuse rating am A
    Electrical connectionsmm²
    Liaison frigorifique
    Suction pipe diameterinches1”1”1/81”1/81”1/81”1/8
    Liquid pipe diameterinches1/2”1/2”5/8”5/8”5/8”
    Max lengthm10001000100010001000
    Max heightm50/4050/4050/4050/4050/40
    Refrigerant / GWPR410A/2088R410A/2088R410A/2088R410A/2088R410A/2088
    Charge (5 m)kg1010101010
    Additional chargeg/m
    Actions Request a quote Request a quote Request a quote Request a quote Request a quote
  • Accessories and options
  • Central controller “touch screen”

    Central controller “touch screen”

    Réf. : 7ACELH023

    Appareils : Mini FlowLogic II/FlowLogic III

    Central control, single unit control, group control, max. 256 units, weekly timer, clock, mode cooling/heating/auto/airflow/dehumidification, temperature, fan speed, fan direction.

    Mini central controller

    Mini central controller

    Réf. : 7ACELH025

    Appareils : Mini FlowLogic II/FlowLogic III

    32 indoor units max., individual control, group control, central control, weekly timer, error display.

    Gather pipe kit for 2 outdoor groups

    Gather pipe kit for 2 outdoor groups

    Réf. : 7ACFHH013

    Appareils : FlowLogic III/Water FlowLogic

    Refrigerant gathering

    Gather pipe kit for 3 outdoor groups

    Gather pipe kit for 3 outdoor groups

    Réf. : 7ACFHH014

    Appareils : FlowLogic III/Water FlowLogic

    Refrigerant gathering

    Manifold pipe (gas + liquid)

    Manifold pipe (gas + liquid)

    Réf. : 7ACFHH001

    Appareils : Mini FlowLogic II/FlowLogic III/Water FlowLogic

    Refrigerant gathering

    Manifold pipe (gas + liquid)

    Manifold pipe (gas + liquid)

    Réf. : 7ACFHH002

    Appareils : Mini FlowLogic II/FlowLogic III/Water FlowLogic

    Refrigerant gathering

    Manifold pipe (gas + liquid)

    Manifold pipe (gas + liquid)

    Réf. : 7ACFHH003

    Appareils : FlowLogic III/Water FlowLogic

    Refrigerant gathering

    Manifold pipe (gas + liquid)

    Manifold pipe (gas + liquid)

    Réf. : 7ACFHH004

    Appareils : FlowLogic III/Water FlowLogic

    Refrigerant gathering

    Manifold pipe (gas + liquid)

    Manifold pipe (gas + liquid)

    Réf. : 7ACFHH015

    Appareils : FlowLogic III/Water FlowLogic

    Refrigerant gathering

    Central controller gateway and ModBus/RTU

    Central controller gateway and ModBus/RTU

    Réf. : 7ACELH027

    Appareils : Mini FlowLogic II/FlowLogic III/Water FlowLogic

    RWV06 and RWV08 adaptor and ModBus/RTU gateway

    Maintenance tool

    Maintenance tool

    Réf. : 7ACELH014

    Appareils : Mini FlowLogic II/FlowLogic III/Water FlowLogic

    Working parameters monitoring and recording tool
  • Technical documentation

These products

may also be interested for you

DBV

Ducted medium static pressure

Ducted medium static pressure

DBV
See the product

CDM R32

Cassette multisplit

Cassette multisplit

CDM R32
See the product

FFM

Floor ceiling monosplit

Floor ceiling monosplit

FFM
See the product

GCAO

Water source fixed speed - Compatible with HHF-CAF-DAF

Water source fixed speed - Compatible with HHF-CAF-DAF

GCAO
See the product

DDV

Ducted low static pressure

Ducted low static pressure

DDV
See the product

DDB R410A

Ducted high static pressure monosplit

Ducted high static pressure monosplit

DDB R410A
See the product

Are you an individual ?

Airwell general public